Software-defined testing
Define, deploy and update test workflows and firmware across your factory and fleet.
VIN
SN-9000001
FAIL
Connectors
- BMU
- PDU ETH
- Inline 1
- Zonal-HV
Test readings
FAILBMU
PASSPin Check Reading and limits Result
10 11
Continuity
0.1 0.55 Ω 1
10 GND
Isolation
70k 100 kΩ 130k
11 GND
Isolation
70k 100 kΩ 130k
PDU ETH
PASSPin Check Reading and limits Result
1 2
Continuity
0.1 0.55 Ω 1
1 GND
Isolation
70k 100 kΩ 130k
2 GND
Isolation
70k 100 kΩ 130k
Inline 1
FAILPin Check Reading and limits Result
2 3
Continuity
0.1 3 Ω 1
2 GND
Isolation
8M 14 MΩ 20M
3 GND
Isolation
8M 14 MΩ 20M
Pin 2 3 reads open: check the terminal crimp.
Zonal-HV
FAILPin Check Reading and limits Result
6 23
Continuity
0.1 0.55 Ω 1
6 GND
Isolation
50M 16.7 MΩ 180M
23 GND
Isolation
50M 115 MΩ 180M
Pin 6 GND leaks to the chassis: check the insulation.